Abstracto

High Performance Liquid Chromatographic Assay Of Famotidine In Pharmaceuticals

K.Basavaiah, H.C.Prameela, U.Chandrashekar, B.C.Somashekar


A rapid assay method for the determination of famotidine in pharmaceutical preparations has been developed for assessment of product quality utilising high-performance liquid chromatography(HPLC). The HPLC separation could be undertaken on a reversed phase Accurasil SS C18 (5 m) column (25 cm x 4.6 mm i.d.) by using a mobile phase consisting of acetonitrile- 0.1% phosphoric acid (pH 3.0) (80:20) at a flow rate 1.0 ml/min. The detector wavelength was at 268 nm with a sensitivity of 0.2 a.u.f.s. The calibration graph was linear from 5.0 to 330 g/ml with the limits of detection(LOD) and qunatification(LOQ) being 1.0 and 3.0 g/ml, respectively. The method was validated according to the current ICH guidelines including assay of commercial tablets. Recoveries ranged from 96.28 to 102.21 %. The exipients present in the tablets did not interfere in the method.


Descargo de responsabilidad: este resumen se tradujo utilizando herramientas de inteligencia artificial y aún no ha sido revisado ni verificado.

Indexado en

  • CAS
  • Google Académico
  • Abrir puerta J
  • Infraestructura Nacional del Conocimiento de China (CNKI)
  • CiteFactor
  • Cosmos SI
  • Biblioteca de revistas electrónicas
  • Directorio de indexación de revistas de investigación (DRJI)
  • Laboratorios secretos de motores de búsqueda
  • ICMJE

Ver más

Flyer